{"id":1907,"date":"2020-04-15T04:14:30","date_gmt":"2020-04-15T04:14:30","guid":{"rendered":"https:\/\/awtaproducttesting.swim.net.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/"},"modified":"2020-04-15T04:14:30","modified_gmt":"2020-04-15T04:14:30","slug":"testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012","status":"publish","type":"news","link":"https:\/\/awtaproducttesting.com.au\/fr\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/","title":{"rendered":"Test des v\u00eatements de protection pour la sant\u00e9 selon ANSI\/AAMI PB70:2012"},"content":{"rendered":"<p><strong><em>Textile Exigence : <\/em><\/strong><em>Protection contre les produits chimiques liquides - D\u00e9termination de la r\u00e9sistance des mat\u00e9riaux \u00e0 la p\u00e9n\u00e9tration des liquides<\/em><\/p>\n<p>En cette p\u00e9riode unique de pand\u00e9mie du virus COVID-19, AWTA Product Testing a la capacit\u00e9 de tester les textiles de soins de sant\u00e9 selon les crit\u00e8res suivants <strong><em>ANSI\/AAMI PB70:2012.&nbsp;<\/em><\/strong><\/p>\n<p>Ce test permet de classer les textiles du niveau 1 au niveau 4 en fonction du niveau de protection contre la p\u00e9n\u00e9tration des fluides :<\/p>\n<ul>\n<li>Le niveau 1 offre une faible protection<\/li>\n<li>Niveau 4 de protection \u00e9lev\u00e9e<\/li>\n<\/ul>\n<p>AWTA Product Testing peut proposer des tests de niveau 3 - protection mod\u00e9r\u00e9e contre la p\u00e9n\u00e9tration des fluides.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" style=\"margin-right: auto; margin-left: auto; display: block;\" src=\"\/app\/images\/Healthcare_Protective_clothing.jpg\" alt=\"\" width=\"672\" height=\"672\" \/><\/p>\n<p>Le niveau 4 est le niveau souhait\u00e9 car il offre une barri\u00e8re de protection contre la p\u00e9n\u00e9tration virale. Malheureusement, notre laboratoire n'est pas en mesure d'atteindre ce niveau et nous ne connaissons pas d'installation en Australasie qui soit en mesure de le faire.<\/p>\n<p>Ce laboratoire peut toutefois proposer des tests selon : <em>V\u00eatements de protection - Protection contre les produits chimiques liquides - D\u00e9termination de la r\u00e9sistance des mat\u00e9riaux \u00e0 la p\u00e9n\u00e9tration des liquides<\/em><\/p>\n<p>Le laboratoire est accr\u00e9dit\u00e9 par la NATA pour effectuer ce test conform\u00e9ment \u00e0 la norme ISO 6530 et Standards Australia a adopt\u00e9 cette m\u00e9thode comme suit <em><strong>ASISO 6530.<\/strong><\/em><\/p>\n<p>La m\u00e9thode permet de mesurer la capacit\u00e9 d'un textile \u00e0 r\u00e9sister \u00e0 la p\u00e9n\u00e9tration d'un liquide, qu'il s'agisse d'un produit chimique ou d'un sang synth\u00e9tique.<\/p>\n<p>Le test fournit les donn\u00e9es suivantes sous forme de pourcentages :<\/p>\n<ul>\n<li>Indice de p\u00e9n\u00e9tration<\/li>\n<li>Indice de r\u00e9pulsion<\/li>\n<li>Indice d'absorption<\/li>\n<\/ul>\n<p>Ces essais pourraient contribuer \u00e0 la mise au point de textiles de soins de sant\u00e9 dont le besoin se fait cruellement sentir. <strong>localement<\/strong> en ces temps incertains.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>CONTACTEZ-NOUS :<\/strong><\/p>\n<p>Pour plus d'informations ou pour conna\u00eetre les prix des tests ci-dessus, veuillez nous contacter : <strong><em>PH : 03 9371 2400 ou Email :&nbsp;<\/em><\/strong><em><a href=\"mailto:producttesting@awta.com.au\">producttesting@awta.com.au<\/a><\/em><\/p>","protected":false},"excerpt":{"rendered":"<p>Exigence en mati\u00e8re de textiles : Protection contre les produits chimiques liquides - D\u00e9termination de la r\u00e9sistance des mat\u00e9riaux \u00e0 la p\u00e9n\u00e9tration des liquides En cette p\u00e9riode unique de l'ann\u00e9e CO...<\/p>","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false},"class_list":["post-1907","news","type-news","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Testing Healthcare Protective Clothing according to ANSI\/AAMI PB70:2012 - AWTA Product Testing<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/awtaproducttesting.com.au\/fr\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Testing Healthcare Protective Clothing according to ANSI\/AAMI PB70:2012 - AWTA Product Testing\" \/>\n<meta property=\"og:description\" content=\"Textile Requirement: Protective Against Liquid chemicals &#8211; Determination of Resistance of Materials to Penetration of Liquids During these unique times of the CO\u2026\" \/>\n<meta property=\"og:url\" content=\"https:\/\/awtaproducttesting.com.au\/fr\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/\" \/>\n<meta property=\"og:site_name\" content=\"AWTA Product Testing\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/\",\"url\":\"https:\/\/awtaproducttesting.com.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/\",\"name\":\"Testing Healthcare Protective Clothing according to ANSI\/AAMI PB70:2012 - AWTA Product Testing\",\"isPartOf\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#website\"},\"datePublished\":\"2020-04-15T04:14:30+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/awtaproducttesting.com.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/awtaproducttesting.com.au\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\/\/awtaproducttesting.com.au\/news\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Testing Healthcare Protective Clothing according to ANSI\/AAMI PB70:2012\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#website\",\"url\":\"https:\/\/awtaproducttesting.com.au\/\",\"name\":\"AWTA Product Testing\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/awtaproducttesting.com.au\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#organization\",\"name\":\"AWTA Product Testing\",\"url\":\"https:\/\/awtaproducttesting.com.au\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg\",\"contentUrl\":\"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg\",\"width\":2560,\"height\":1580,\"caption\":\"AWTA Product Testing\"},\"image\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Testing Healthcare Protective Clothing according to ANSI\/AAMI PB70:2012 - AWTA Product Testing","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/awtaproducttesting.com.au\/fr\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/","og_locale":"fr_FR","og_type":"article","og_title":"Testing Healthcare Protective Clothing according to ANSI\/AAMI PB70:2012 - AWTA Product Testing","og_description":"Textile Requirement: Protective Against Liquid chemicals &#8211; Determination of Resistance of Materials to Penetration of Liquids During these unique times of the CO\u2026","og_url":"https:\/\/awtaproducttesting.com.au\/fr\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/","og_site_name":"AWTA Product Testing","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/awtaproducttesting.com.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/","url":"https:\/\/awtaproducttesting.com.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/","name":"Testing Healthcare Protective Clothing according to ANSI\/AAMI PB70:2012 - AWTA Product Testing","isPartOf":{"@id":"https:\/\/awtaproducttesting.com.au\/#website"},"datePublished":"2020-04-15T04:14:30+00:00","breadcrumb":{"@id":"https:\/\/awtaproducttesting.com.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/awtaproducttesting.com.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/awtaproducttesting.com.au\/news\/testing-healthcare-protective-clothing-according-to-ansi-aami-pb70-2012\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/awtaproducttesting.com.au\/"},{"@type":"ListItem","position":2,"name":"News","item":"https:\/\/awtaproducttesting.com.au\/news\/"},{"@type":"ListItem","position":3,"name":"Testing Healthcare Protective Clothing according to ANSI\/AAMI PB70:2012"}]},{"@type":"WebSite","@id":"https:\/\/awtaproducttesting.com.au\/#website","url":"https:\/\/awtaproducttesting.com.au\/","name":"Tests de produits de l'AWTA","description":"","publisher":{"@id":"https:\/\/awtaproducttesting.com.au\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/awtaproducttesting.com.au\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/awtaproducttesting.com.au\/#organization","name":"Tests de produits de l'AWTA","url":"https:\/\/awtaproducttesting.com.au\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/","url":"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg","contentUrl":"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg","width":2560,"height":1580,"caption":"AWTA Product Testing"},"image":{"@id":"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/awtaproducttesting.com.au\/fr\/wp-json\/wp\/v2\/news\/1907","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/awtaproducttesting.com.au\/fr\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/awtaproducttesting.com.au\/fr\/wp-json\/wp\/v2\/types\/news"}],"wp:attachment":[{"href":"https:\/\/awtaproducttesting.com.au\/fr\/wp-json\/wp\/v2\/media?parent=1907"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}