{"id":1867,"date":"2024-02-14T04:38:16","date_gmt":"2024-02-14T04:38:16","guid":{"rendered":"https:\/\/awtaproducttesting.swim.net.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/"},"modified":"2024-02-14T04:38:16","modified_gmt":"2024-02-14T04:38:16","slug":"pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2","status":"publish","type":"news","link":"https:\/\/awtaproducttesting.com.au\/it\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/","title":{"rendered":"ASNZS 4200.1:2017 - Prove su membrane edilizie flessibili e sottofondi (Parte 1: Materiali)"},"content":{"rendered":"<p>L'attuale edizione 2022 del National Construction Code (NCC) richiede che i materiali di tipo sarking utilizzati per l'impermeabilizzazione di tetti e pareti siano conformi alla norma ASNZS 4200.1.<\/p>\n<p>Questo include la costruzione di pareti esterne come specificato nella sezione F8D3. ASNZS 4200.1 classifica le membrane flessibili in base alle propriet\u00e0 del materiale. Le membrane adatte possono quindi essere selezionate in base alla classificazione del servizio. Le classi di impiego vanno da Extra Heavy a Extra Light, in base ai parametri fisici di resistenza a trazione, resistenza alla lacerazione dei bordi e resistenza allo scoppio.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/app\/images\/Wall-Sarking.jpg\" alt=\"\" width=\"406\" height=\"311\" style=\"display: block; margin-left: auto; margin-right: auto;\" \/><\/p>\n<p>A seconda della zona climatica, \u00e8 richiesto un livello minimo di permeabilit\u00e0 al vapore. Le membrane per il controllo del vapore di classe 3 e 4, determinate da prove di laboratorio, soddisfano i requisiti della sezione F8D3. Anche le membrane flessibili svolgono un ruolo nella determinazione dell'efficienza energetica delle pareti. L'emittanza della superficie interna di una membrana centrale riflettente viene considerata nel calcolo dei valori R in conformit\u00e0 con ASNZS 4859.2 .<\/p>\n<p>L'emittanza infrarossa della superficie viene misurata e classificata come IR riflettente, IR semi-riflettente o IR non riflettente secondo ASNZS 4200.1.<\/p>\n<p><span style=\"text-decoration: underline; font-size: 12pt;\"><strong>Come possiamo aiutarvi?<\/strong><\/span><\/p>\n<p>- AWTA Product testing \u00e8 accreditata NATA per la maggior parte dei test che misurano le propriet\u00e0 dei materiali e determinano le classificazioni risultanti in base alle prestazioni.<\/p>\n<p>- Il laboratorio offre anche prove per determinare le classificazioni opzionali dei materiali, come previsto dall'Appendice A di ASNZS 4200.1.<\/p>\n<p>- Tra questi, la resistenza all'esposizione ai raggi UV, la corrosione superficiale delle superfici a bassa emittanza, il ritiro termico e la classificazione dell'assorbenza dell'acqua in superficie.<\/p>\n<p>- Pur essendo facoltative, queste classificazioni aggiuntive dei materiali offrono un vantaggio di marketing quando i prodotti classificati di conseguenza aggiungono valore a un'installazione.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/app\/images\/sarking_roof_1.jpg\" alt=\"\" width=\"417\" height=\"299\" style=\"display: block; margin-left: auto; margin-right: auto;\" \/><\/p>\n<p><span style=\"font-size: 12pt;\"><strong><span style=\"text-decoration: underline;\">Contattateci:<\/span><\/strong><\/span><\/p>\n<p>Se desiderate ulteriori informazioni su <em><strong>membrane e sottofondi malleabili per l'edilizia, Parte 1: test<\/strong><\/em> o i nostri servizi di analisi in generale, contattateci come indicato di seguito:&nbsp;<\/p>\n<p><strong>Telefono: +61 (03) 9371 2400 O&nbsp;&nbsp;&nbsp;<\/strong><strong>&nbsp;E-mail:<\/strong><strong><a href=\"mailto:producttesting@awta.com.au\"><\/a><a href=\"mailto:producttesting@awta.com.au\">producttesting@awta.com.au<\/a><\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>The current 2022 issue of the National Construction Code (NCC) calls for sarking type materials used for the purpose of weather proofing roofs and walls, to comply wit\u2026<\/p>","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false},"class_list":["post-1867","news","type-news","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ASNZS 4200.1:2017 - Pliable building membranes and underlay testing (Part 1: Materials) - AWTA Product Testing<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/awtaproducttesting.com.au\/it\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ASNZS 4200.1:2017 - Pliable building membranes and underlay testing (Part 1: Materials) - AWTA Product Testing\" \/>\n<meta property=\"og:description\" content=\"The current 2022 issue of the National Construction Code (NCC) calls for sarking type materials used for the purpose of weather proofing roofs and walls, to comply wit\u2026\" \/>\n<meta property=\"og:url\" content=\"https:\/\/awtaproducttesting.com.au\/it\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/\" \/>\n<meta property=\"og:site_name\" content=\"AWTA Product Testing\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/\",\"url\":\"https:\/\/awtaproducttesting.com.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/\",\"name\":\"ASNZS 4200.1:2017 - Pliable building membranes and underlay testing (Part 1: Materials) - AWTA Product Testing\",\"isPartOf\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#website\"},\"datePublished\":\"2024-02-14T04:38:16+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/awtaproducttesting.com.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/awtaproducttesting.com.au\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\/\/awtaproducttesting.com.au\/news\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ASNZS 4200.1:2017 &#8211; Pliable building membranes and underlay testing (Part 1: Materials)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#website\",\"url\":\"https:\/\/awtaproducttesting.com.au\/\",\"name\":\"AWTA Product Testing\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/awtaproducttesting.com.au\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#organization\",\"name\":\"AWTA Product Testing\",\"url\":\"https:\/\/awtaproducttesting.com.au\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg\",\"contentUrl\":\"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg\",\"width\":2560,\"height\":1580,\"caption\":\"AWTA Product Testing\"},\"image\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ASNZS 4200.1:2017 - Pliable building membranes and underlay testing (Part 1: Materials) - AWTA Product Testing","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/awtaproducttesting.com.au\/it\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/","og_locale":"it_IT","og_type":"article","og_title":"ASNZS 4200.1:2017 - Pliable building membranes and underlay testing (Part 1: Materials) - AWTA Product Testing","og_description":"The current 2022 issue of the National Construction Code (NCC) calls for sarking type materials used for the purpose of weather proofing roofs and walls, to comply wit\u2026","og_url":"https:\/\/awtaproducttesting.com.au\/it\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/","og_site_name":"AWTA Product Testing","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/awtaproducttesting.com.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/","url":"https:\/\/awtaproducttesting.com.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/","name":"ASNZS 4200.1:2017 - Pliable building membranes and underlay testing (Part 1: Materials) - AWTA Product Testing","isPartOf":{"@id":"https:\/\/awtaproducttesting.com.au\/#website"},"datePublished":"2024-02-14T04:38:16+00:00","breadcrumb":{"@id":"https:\/\/awtaproducttesting.com.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/awtaproducttesting.com.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/awtaproducttesting.com.au\/news\/pliable-building-membranes-and-underlays-part-1-materials-asnzs-4200-1-2017-testing-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/awtaproducttesting.com.au\/"},{"@type":"ListItem","position":2,"name":"News","item":"https:\/\/awtaproducttesting.com.au\/news\/"},{"@type":"ListItem","position":3,"name":"ASNZS 4200.1:2017 &#8211; Pliable building membranes and underlay testing (Part 1: Materials)"}]},{"@type":"WebSite","@id":"https:\/\/awtaproducttesting.com.au\/#website","url":"https:\/\/awtaproducttesting.com.au\/","name":"Test di prodotto AWTA","description":"","publisher":{"@id":"https:\/\/awtaproducttesting.com.au\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/awtaproducttesting.com.au\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/awtaproducttesting.com.au\/#organization","name":"Test di prodotto AWTA","url":"https:\/\/awtaproducttesting.com.au\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/","url":"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg","contentUrl":"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg","width":2560,"height":1580,"caption":"AWTA Product Testing"},"image":{"@id":"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/news\/1867","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/types\/news"}],"wp:attachment":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/media?parent=1867"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}