{"id":1890,"date":"2022-04-05T01:24:24","date_gmt":"2022-04-05T01:24:24","guid":{"rendered":"https:\/\/awtaproducttesting.swim.net.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/"},"modified":"2022-04-05T01:24:24","modified_gmt":"2022-04-05T01:24:24","slug":"national-construction-code-update-for-fire-performance-of-textiles","status":"publish","type":"news","link":"https:\/\/awtaproducttesting.com.au\/it\/news\/national-construction-code-update-for-fire-performance-of-textiles\/","title":{"rendered":"Aggiornamento del Codice nazionale delle costruzioni - Prestazioni al fuoco dei tessuti"},"content":{"rendered":"<p>Il Codice nazionale delle costruzioni<strong> (<\/strong>NCC) viene rilasciato su un ciclo di tre anni, con il codice del 2019 in vigore fino al 1\u00b0 gennaio 2019.<sup>st<\/sup> Maggio 2022.<\/p>\n<p>Il volume 1 del codice si estende agli edifici pubblici. A causa delle modifiche critiche necessarie per affrontare, ad esempio, i rivestimenti e i sistemi di pareti esterne, nel marzo 2018 \u00e8 stato emesso un emendamento al codice. Il codice ora include&nbsp;<strong><em>AS 5113 - 2016, Test di propagazione del fuoco e classificazione delle pareti esterne degli edifici<\/em>.&nbsp;<\/strong>Questo standard, sebbene accettato dal codice modificato nella sua forma attuale, \u00e8 ancora in fase di revisione e, cosa importante per il nostro interesse, chiarisce che le tende tessili non sono considerate parte di un sistema di facciata o di parete esterna.<\/p>\n<p>L'NCC offre ora due opzioni per dimostrare la conformit\u00e0:<\/p>\n<p><strong><span style=\"text-decoration: underline;\"><span style=\"font-size: 12pt;\">Ritenuto soddisfacente:<\/span><\/span><br \/> <\/strong>Questo \u00e8 l'approccio pi\u00f9 semplice e probabilmente \u00e8 il percorso da seguire per un'applicazione tessile, ad eccezione di alcuni materiali di protezione e isolamento che possono essere parte di una Performance Solution.<\/p>\n<p>Il codice fornisce requisiti di prestazione per determinare se un prodotto \u00e8 considerato conforme alle disposizioni. Un esempio \u00e8 l'uso della sezione C1.10, che riguarda la maggior parte dei tessuti per interni e prescrive metodi di prova e requisiti di prestazione per uso finale. Il rispetto di questi requisiti fa s\u00ec che il prodotto sia \u201cconsiderato conforme\u201d alle disposizioni del codice.<\/p>\n<p><span style=\"text-decoration: underline; font-size: 12pt;\"><strong>Soluzioni per le prestazioni, precedentemente denominate soluzioni alternative:<\/strong><\/span><\/p>\n<p>Per i progetti o le installazioni pi\u00f9 complesse pu\u00f2 essere necessario sviluppare una soluzione prestazionale per dimostrare il rispetto dei requisiti prestazionali. Potrebbe essere necessario coinvolgere diverse parti interessate, come periti edili e ingegneri. Il codice incoraggia l'interazione con l'autorit\u00e0 di omologazione competente per garantire che la soluzione finale soddisfi le esigenze di documentazione e di approvazione finale. Le autorit\u00e0 di omologazione devono essere consultate senza diventare parte della soluzione, per mantenere la neutralit\u00e0 delle loro valutazioni.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/app\/images\/Building_on_fire.jpg\" alt=\"\" width=\"509\" height=\"403\" style=\"display: block; margin-left: auto; margin-right: auto;\" \/><\/p>\n<p><strong><br \/>Capire il fuoco e i tessuti<\/strong><\/p>\n<p>I requisiti di resistenza al fuoco dei tessuti per interni sono delineati nella sezione C1.10 dell'NCC, degli standard australiani e del Codice delle strutture temporanee. Qui troviamo soluzioni ritenute soddisfacenti per imbottiti, rivestimenti murali, arredi per finestre, pavimenti e altro ancora.<\/p>\n<p>L'Australian Building Codes Board nella sua presentazione sugli incendi \u201cWhat Practitioners Need to Know\u201d ci ricorda il triangolo del fuoco, ovvero i 3 elementi che si uniscono per rendere possibile un incendio. Questi sono: ossigeno, calore e combustibile.<\/p>\n<p style=\"text-align: center;\"><span style=\"font-size: 12pt;\"><strong><em>\u201cIl fuoco \u00e8 il prodotto di una reazione chimica tra l'ossigeno dell'aria e i gas rilasciati dal combustibile\u201d.\u201d<\/em><\/strong><\/span><\/p>\n<p>Ogni incendio attraversa una fase di crescita, poi raggiunge il flashover e diventa completamente sviluppato. Poi passa alla fase di decadimento, durante la quale uno o pi\u00f9 elementi del triangolo si riducono, ad esempio il combustibile si esaurisce. L'elemento di interesse \u00e8 il combustibile e l'effetto o il risultato della sua disponibilit\u00e0 in presenza di ossigeno e calore.<\/p>\n<p>Il comportamento di combustione del combustibile tessile \u00e8 in gran parte determinato dalla composizione del tessuto:<\/p>\n<ul>\n<li>I materiali cellulosici, come il cotone o il rayon viscosa, si incendiano facilmente e si diffondono rapidamente decomponendosi in ceneri leggere.<\/li>\n<li>I materiali termoplastici, come il nylon e il poliestere, tendono a ritirarsi in presenza di calore, ma una quantit\u00e0 sufficiente di calore li far\u00e0 fondere e gocciolare o divampare una fiamma.<\/li>\n<li>Le fibre proteiche come la lana o la seta tendono ad autoestinguersi quando viene rimossa la fonte di fiamma.<\/li>\n<li>Le fibre tessili specializzate, come le aramidi, sono resistenti alla fiamma e vengono utilizzate in applicazioni specializzate come l'industria aerospaziale e alcuni indumenti da lavoro e sportivi.\n<\/li>\n<\/ul>\n<p><span style=\"text-decoration: underline; font-size: 12pt;\"><strong>Per ulteriori informazioni:<\/strong><\/span><\/p>\n<p>Contattateci per discutere le vostre esigenze di test antincendio al numero:<strong><em>&nbsp;PH: 03 9371 2400 o e-mail:&nbsp;<a href=\"mailto:producttesting@awta.com.au\"><\/a><a href=\"mailto:producttesting@awta.com.au\">producttesting@awta.com.au<\/a><\/em><\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>Il National Construction Code (NCC) viene pubblicato con un ciclo di tre anni: il codice del 2019 \u00e8 in vigore fino al 1\u00b0 maggio 2022. Il volume 1 del codice si estende agli edifici pubblici...<\/p>","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false},"class_list":["post-1890","news","type-news","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>National Construction Code Update \u2013 Fire Performance of Textiles - AWTA Product Testing<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/awtaproducttesting.com.au\/it\/news\/national-construction-code-update-for-fire-performance-of-textiles\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"National Construction Code Update \u2013 Fire Performance of Textiles - AWTA Product Testing\" \/>\n<meta property=\"og:description\" content=\"The National Construction Code (NCC) is released on a 3 year cycle, with the 2019 code being current until the 1st May 2022. Volume 1 of the code extends to public bui\u2026\" \/>\n<meta property=\"og:url\" content=\"https:\/\/awtaproducttesting.com.au\/it\/news\/national-construction-code-update-for-fire-performance-of-textiles\/\" \/>\n<meta property=\"og:site_name\" content=\"AWTA Product Testing\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/\",\"url\":\"https:\/\/awtaproducttesting.com.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/\",\"name\":\"National Construction Code Update \u2013 Fire Performance of Textiles - AWTA Product Testing\",\"isPartOf\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#website\"},\"datePublished\":\"2022-04-05T01:24:24+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/awtaproducttesting.com.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/awtaproducttesting.com.au\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\/\/awtaproducttesting.com.au\/news\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"National Construction Code Update \u2013 Fire Performance of Textiles\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#website\",\"url\":\"https:\/\/awtaproducttesting.com.au\/\",\"name\":\"AWTA Product Testing\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/awtaproducttesting.com.au\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#organization\",\"name\":\"AWTA Product Testing\",\"url\":\"https:\/\/awtaproducttesting.com.au\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg\",\"contentUrl\":\"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg\",\"width\":2560,\"height\":1580,\"caption\":\"AWTA Product Testing\"},\"image\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"National Construction Code Update \u2013 Fire Performance of Textiles - AWTA Product Testing","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/awtaproducttesting.com.au\/it\/news\/national-construction-code-update-for-fire-performance-of-textiles\/","og_locale":"it_IT","og_type":"article","og_title":"National Construction Code Update \u2013 Fire Performance of Textiles - AWTA Product Testing","og_description":"The National Construction Code (NCC) is released on a 3 year cycle, with the 2019 code being current until the 1st May 2022. Volume 1 of the code extends to public bui\u2026","og_url":"https:\/\/awtaproducttesting.com.au\/it\/news\/national-construction-code-update-for-fire-performance-of-textiles\/","og_site_name":"AWTA Product Testing","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/awtaproducttesting.com.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/","url":"https:\/\/awtaproducttesting.com.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/","name":"National Construction Code Update \u2013 Fire Performance of Textiles - AWTA Product Testing","isPartOf":{"@id":"https:\/\/awtaproducttesting.com.au\/#website"},"datePublished":"2022-04-05T01:24:24+00:00","breadcrumb":{"@id":"https:\/\/awtaproducttesting.com.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/awtaproducttesting.com.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/awtaproducttesting.com.au\/news\/national-construction-code-update-for-fire-performance-of-textiles\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/awtaproducttesting.com.au\/"},{"@type":"ListItem","position":2,"name":"News","item":"https:\/\/awtaproducttesting.com.au\/news\/"},{"@type":"ListItem","position":3,"name":"National Construction Code Update \u2013 Fire Performance of Textiles"}]},{"@type":"WebSite","@id":"https:\/\/awtaproducttesting.com.au\/#website","url":"https:\/\/awtaproducttesting.com.au\/","name":"Test di prodotto AWTA","description":"","publisher":{"@id":"https:\/\/awtaproducttesting.com.au\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/awtaproducttesting.com.au\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/awtaproducttesting.com.au\/#organization","name":"Test di prodotto AWTA","url":"https:\/\/awtaproducttesting.com.au\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/","url":"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg","contentUrl":"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg","width":2560,"height":1580,"caption":"AWTA Product Testing"},"image":{"@id":"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/news\/1890","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/types\/news"}],"wp:attachment":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/media?parent=1890"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}