{"id":1902,"date":"2020-07-29T01:51:00","date_gmt":"2020-07-29T01:51:00","guid":{"rendered":"https:\/\/awtaproducttesting.swim.net.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/"},"modified":"2020-07-29T01:51:00","modified_gmt":"2020-07-29T01:51:00","slug":"liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities","status":"publish","type":"news","link":"https:\/\/awtaproducttesting.com.au\/it\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/","title":{"rendered":"Prestazioni di barriera ai liquidi e classificazione degli indumenti protettivi per l'uso in strutture sanitarie"},"content":{"rendered":"<p><strong>ANSI\/AAMI PB70:2012<\/strong> - Prestazioni di barriera ai liquidi e classificazione di indumenti e teli protettivi destinati all'uso in strutture sanitarie.<\/p>\n<p>Il<em><strong> ANSI\/AAMI PB 70:2012<\/strong><\/em> La norma stabilisce i requisiti minimi di prestazione della barriera, un sistema di classificazione e i relativi requisiti di etichettatura per gli indumenti protettivi, i teli chirurgici e gli accessori per teli destinati all'uso nelle strutture sanitarie.<\/p>\n<p>Il sistema di classificazione classifica gli indumenti protettivi, sia monouso che riutilizzabili, in livelli di barriera. I quattro livelli misurano essenzialmente il livello di resistenza alla penetrazione dei fluidi.<\/p>\n<p>I livelli misurano livelli di protezione sempre pi\u00f9 elevati: il livello 1 offre protezione contro i liquidi che possono schizzare sull'utente, fino al livello 4 che offre resistenza alla penetrazione di liquidi e virus.<\/p>\n<p><strong>Livello 1 - Protezione minima contro gli spruzzi di liquidi<\/strong><\/p>\n<p><strong>Livello 2 - Basso livello di protezione contro l'impatto e la penetrazione di liquidi.<\/strong><\/p>\n<p><strong>Livello 3 - Livello moderato di protezione contro l'impatto e la penetrazione di liquidi.<\/strong><\/p>\n<p><strong>Livello 4 - Alto livello di protezione contro la penetrazione di liquidi e virus.<br \/><\/strong><\/p>\n<p><em><br \/>AWTA Product Testing \u00e8 in grado di eseguire test fino al livello 3 incluso.<\/p>\n<p><\/em>.I test richiesti per la classificazione del livello sono due:<\/p>\n<p>AATCC 42 - Resistenza all'acqua: Test di penetrazione dell'impatto<\/p>\n<p>Questo test misura la resistenza alla penetrazione dell'acqua per impatto o spruzzi.<\/p>\n<p>AATCC 127 - Resistenza all'acqua: Test di pressione idrostatica<\/p>\n<p>Questo test misura la resistenza alla penetrazione dell'acqua sotto pressione idrostatica o sotto colonna d'acqua.<\/p>\n<p>La tabella seguente mostra i requisiti di prestazione per la classificazione dei livelli.<\/p>\n<p><strong>&nbsp;&nbsp;&nbsp;<span style=\"font-size: 10pt;\"><img loading=\"lazy\" decoding=\"async\" src=\"\/app\/images\/PPE_Table.png\" alt=\"\" width=\"525\" height=\"77\" \/><\/span><\/strong><\/p>\n<p>La norma ANSI\/AAMI PB 70:2012 identifica le zone critiche da sottoporre a test di conformit\u00e0.<\/p>\n<p><strong>Zone critiche di un camice destinato ad applicazioni chirurgiche.<\/strong><\/p>\n<p>&nbsp;<img loading=\"lazy\" decoding=\"async\" src=\"\/app\/images\/Gown_1st.jpg\" alt=\"\" width=\"477\" height=\"506\" style=\"margin-right: auto; margin-left: auto; display: block;\" \/><\/p>\n<p><strong>&nbsp;<\/strong><\/p>\n<p><span style=\"color: #999999;\"><em>NOTA: Schema estratto dalla norma ANSI\/AAMI PB 70:2012.<\/em><\/span><\/p>\n<p><strong>Zone critiche su camici destinati ad applicazioni di isolamento<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"\/app\/images\/Giown_2.jpg\" alt=\"\" width=\"441\" height=\"472\" style=\"margin-right: auto; margin-left: auto; display: block;\" \/><\/p>\n<p><span style=\"color: #999999;\"><em>NOTA: Schema estratto dalla norma ANSI\/AAMI PB 70:2012.<\/em><\/span><\/p>\n<p>Lo standard specifica anche un piano di campionamento per le prove basato su un livello statistico di qualit\u00e0 accettabile (AQL) e un livello di qualit\u00e0 rifiutabile (RQL):<\/p>\n<ul>\n<li>AQL - 4%<\/li>\n<li>RQL - 20%<\/li>\n<\/ul>\n<p>Il numero di test da eseguire per classificare il livello delle merci sfuse dipende quindi da:<\/p>\n<ul>\n<li>Dimensione del lotto<\/li>\n<li>Tipo di ispezione<\/li>\n<li>Livello di ispezione generale<\/li>\n<\/ul>\n<p>Per i dettagli completi delle procedure di prova e del piano di campionamento, consultare la norma ANSI\/AAMI PB70:2012.<\/p>\n<p><strong>Requisiti di etichettatura<\/strong><\/p>\n<p>Ogni camice chirurgico, altro capo di abbigliamento protettivo, telo chirurgico e accessorio per telo deve essere chiaramente etichettato con il suo livello di barriera, come determinato dalle procedure di prova.<\/p>\n<p><strong>Test<\/strong><\/p>\n<p>AWTA Product Testing \u00e8 in grado di offrire test di tipo sviluppo di prodotti singoli o in serie.<\/p>\n<p>Rivolgetevi ai nostri consulenti per conoscere il piano dei prezzi, che pu\u00f2 variare in base al numero di capi da testare secondo il piano di campionamento.<\/p>\n<p><strong>Telefono: (03) 9371 2400 o e-mail:&nbsp;<a><\/a><a><\/a><a href=\"mailto:producttesting@awta.com.au\"><\/a><a href=\"mailto:producttesting@awta.com.au\">producttesting@awta.com.au<\/a><\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>ANSI\/AAMI PB70:2012 - Prestazioni di barriera ai liquidi e classificazione di indumenti e teli protettivi destinati all'uso in strutture sanitarie. La norma ANSI\/AAM...<\/p>","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false},"class_list":["post-1902","news","type-news","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Liquid barrier performance &amp; classification of Protective Apparel for use in Health Care facilities - AWTA Product Testing<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/awtaproducttesting.com.au\/it\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Liquid barrier performance &amp; classification of Protective Apparel for use in Health Care facilities - AWTA Product Testing\" \/>\n<meta property=\"og:description\" content=\"ANSI\/AAMI PB70:2012 &#8211; Liquid barrier performance &amp; classification of protective apparel &amp; drapes intended for use in health care facilities. The ANSI\/AAM\u2026\" \/>\n<meta property=\"og:url\" content=\"https:\/\/awtaproducttesting.com.au\/it\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/\" \/>\n<meta property=\"og:site_name\" content=\"AWTA Product Testing\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/\",\"url\":\"https:\/\/awtaproducttesting.com.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/\",\"name\":\"Liquid barrier performance & classification of Protective Apparel for use in Health Care facilities - AWTA Product Testing\",\"isPartOf\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#website\"},\"datePublished\":\"2020-07-29T01:51:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/awtaproducttesting.com.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/awtaproducttesting.com.au\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\/\/awtaproducttesting.com.au\/news\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Liquid barrier performance &#038; classification of Protective Apparel for use in Health Care facilities\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#website\",\"url\":\"https:\/\/awtaproducttesting.com.au\/\",\"name\":\"AWTA Product Testing\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/awtaproducttesting.com.au\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#organization\",\"name\":\"AWTA Product Testing\",\"url\":\"https:\/\/awtaproducttesting.com.au\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg\",\"contentUrl\":\"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg\",\"width\":2560,\"height\":1580,\"caption\":\"AWTA Product Testing\"},\"image\":{\"@id\":\"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Liquid barrier performance & classification of Protective Apparel for use in Health Care facilities - AWTA Product Testing","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/awtaproducttesting.com.au\/it\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/","og_locale":"it_IT","og_type":"article","og_title":"Liquid barrier performance & classification of Protective Apparel for use in Health Care facilities - AWTA Product Testing","og_description":"ANSI\/AAMI PB70:2012 &#8211; Liquid barrier performance &amp; classification of protective apparel &amp; drapes intended for use in health care facilities. The ANSI\/AAM\u2026","og_url":"https:\/\/awtaproducttesting.com.au\/it\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/","og_site_name":"AWTA Product Testing","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/awtaproducttesting.com.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/","url":"https:\/\/awtaproducttesting.com.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/","name":"Liquid barrier performance & classification of Protective Apparel for use in Health Care facilities - AWTA Product Testing","isPartOf":{"@id":"https:\/\/awtaproducttesting.com.au\/#website"},"datePublished":"2020-07-29T01:51:00+00:00","breadcrumb":{"@id":"https:\/\/awtaproducttesting.com.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/awtaproducttesting.com.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/awtaproducttesting.com.au\/news\/liquid-barrier-performance-classification-of-protective-apparel-for-use-in-health-care-facilities\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/awtaproducttesting.com.au\/"},{"@type":"ListItem","position":2,"name":"News","item":"https:\/\/awtaproducttesting.com.au\/news\/"},{"@type":"ListItem","position":3,"name":"Liquid barrier performance &#038; classification of Protective Apparel for use in Health Care facilities"}]},{"@type":"WebSite","@id":"https:\/\/awtaproducttesting.com.au\/#website","url":"https:\/\/awtaproducttesting.com.au\/","name":"Test di prodotto AWTA","description":"","publisher":{"@id":"https:\/\/awtaproducttesting.com.au\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/awtaproducttesting.com.au\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/awtaproducttesting.com.au\/#organization","name":"Test di prodotto AWTA","url":"https:\/\/awtaproducttesting.com.au\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/","url":"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg","contentUrl":"https:\/\/awtaproducttesting.com.au\/app\/uploads\/2025\/08\/PT-News-Banner-scaled.jpg","width":2560,"height":1580,"caption":"AWTA Product Testing"},"image":{"@id":"https:\/\/awtaproducttesting.com.au\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/news\/1902","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/types\/news"}],"wp:attachment":[{"href":"https:\/\/awtaproducttesting.com.au\/it\/wp-json\/wp\/v2\/media?parent=1902"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}